<link rel="stylesheet" href="assets/fonts/roboto/roboto.css">
Menu

Fluke 810/2026 — Vibration analyzer for mechanical fault diagnosis

Fluke 810/2026 helps identify unbalance, looseness, misalignment and bearing faults in rotating machinery. Enter the machine data, measure with the triaxial accelerometer, and receive a text diagnosis, one of four severity levels and repair recommendations. Spectra and overall vibration support data-quality checks and comparisons before and after maintenance.
  • Current ordering version: 810/2026; PN 6102680
  • Diagnosed faults: Unbalance, looseness, misalignment, bearing faults
  • Rotational speed range: 200…12000 rpm
  • Diagnostic results: Text diagnosis, 4 severity levels, repair recommendations, spectra
  • ADC: 4 channels, 24 bit
  • Availability: On order
  • Manufacturer: Fluke
  • SKU: 01190
Price: on request

Description

Fluke 810/2026 helps identify unbalance, looseness, misalignment and bearing faults in rotating machinery. Enter the machine data, measure with the triaxial accelerometer, and receive a text diagnosis, one of four severity levels and repair recommendations. Spectra and overall vibration support data-quality checks and comparisons before and after maintenance. The 200–12000 rpm range covers motors, pumps, fans, compressors and other equipment. This card describes the manufacturer’s current 810/2026 ordering version; the package includes a triaxial sensor, magnetic mount, cable, battery and carrying case.

Specifications

Current ordering version
810/2026; PN 6102680
Diagnosed faults
Unbalance, looseness, misalignment, bearing faults
Rotational speed range
200…12000 rpm
Diagnostic results
Text diagnosis, 4 severity levels, repair recommendations, spectra
ADC
4 channels, 24 bit
Instrument usable bandwidth
2 Hz…20 kHz
Dynamic range
128 dB
FFT resolution
800 lines; Hanning window
Sensor type
Triaxial accelerometer
Sensor sensitivity and range
100 mV/g ±5% at 25 °C; 80 g peak
Sensor frequency response
Z: 2…7000 Hz ±3 dB; X/Y: 2…5000 Hz ±3 dB
Sensor connection
4-pin M12; TEDS 1451.4
Internal memory
2 GB; slot for additional microSD
Display
5.7″ TFT LCD; 320 × 240; LED backlight
PC connection
Mini-B USB 2.0
Power supply
Li-ion 14.8 V, 2.55 Ah
Battery operation
Typically 8 h; charging 3 h
AC adapter
100…240 V AC; 50/60 Hz
Operating temperature
0…+50 °C
Dimensions and weight
185.6 × 70 × 267.2 mm; 1.9 kg with battery
Current standard package
Analyzer, accelerometer/magnet/pads/cable, battery and adapters, straps, USB cable, guides and case