Fluke MDA-550 Series III — Motor drive analyzer

Fluke MDA-550 Series III guides variable-frequency drive and motor diagnostics from the power input to the shaft. On-screen diagrams show voltage and current connections, while preset profiles reduce manual setup. It checks input unbalance and harmonics, DC-link voltage and ripple, output PWM voltage, V/Hz, dV/dt, overshoot and shaft discharge events.
  • Ordering model: MDA-550-III; PN 5282560
  • Channels and bandwidth: 4 isolated inputs; 500 MHz oscilloscope
  • Guided measurement points: Drive input, DC link, drive output, motor input and shaft
  • Input checks: V/A/Hz, peaks, crest factor, voltage/current unbalance
  • DC-link checks: V DC; V AC ripple; V peak; V peak-to-peak; Hz
  • Availability: On order
  • Manufacturer: Fluke
  • SKU: 01192
Price: on request

Description

Fluke MDA-550 Series III guides variable-frequency drive and motor diagnostics from the power input to the shaft. On-screen diagrams show voltage and current connections, while preset profiles reduce manual setup. It checks input unbalance and harmonics, DC-link voltage and ripple, output PWM voltage, V/Hz, dV/dt, overshoot and shaft discharge events. A four-channel 500 MHz oscilloscope supports additional signal analysis. Supplied high-voltage probes, current clamps and the SVS-500 shaft voltage kit cover the different test points. FlukeView-2 and a Wi-Fi adapter support PC transfer.

Specifications

Ordering model
MDA-550-III; PN 5282560
Channels and bandwidth
4 isolated inputs; 500 MHz oscilloscope
Guided measurement points
Drive input, DC link, drive output, motor input and shaft
Input checks
V/A/Hz, peaks, crest factor, voltage/current unbalance
DC-link checks
V DC; V AC ripple; V peak; V peak-to-peak; Hz
PWM and modulation
V PWM; V/Hz; dV/dt; rise/fall time; overshoot
Shaft voltage
Impulse amplitude, rise/fall time, dV/dt, events/s
Harmonics
DC through 51st; THD/TDD
Extended spectrum
1…9 kHz; 9…150 kHz (20 MHz filter)
DC voltage measurement
≤1000 V with 10:1/100:1 probe; ±(1.5% + 6 counts) at the specified time base
Frequency measurement
1 Hz…500 MHz; ±(0.5% + 2 counts)
Electrical category with probes
CAT III 1000 V / CAT IV 600 V; VPS410-II / VPS421
Direct BNC inputs
A/B/C/D: CAT IV 300 V
Included voltage probes
3 × VPS421 100:1; 1 × VPS410-II-R 10:1
Included current clamps
3 × i400s AC
Shaft test kit
SVS-500: 3 brushes, holder, extension rod and magnetic base
Software and connectivity
Full FlukeView-2; USB and Wi-Fi adapter
Power and carrying
BP291 Li-ion; BC190; C437-II wheeled case